第16回
浜岡原子力発電所5号機における海水流入事象に係る原子炉圧力容器廻りの浄化・保管について
著者:
林 栄昌,進藤 俊哉,今井 富康,山本 優介,向井 紫乃,(中部電力)
発刊日:
公開日:
キーワードタグ:
In the process of achieving cold shutdown of Hamaoka Nuclear Power Station Unit 5 on May 14, 2011, sea water flowed into the reactor and other equipment due to main condenser tube leakage. By clean-up operation, chloride ion concentration went below 10 ppm, the target prescribed to prevent crevice corrosion. On Dec, 2015, the component health assessment had summarized by surveys focusing on material corrosion, deposit and residual chloride. Since, each equipment have been under wet or dry lay-up condition. ...
英字タイトル:
Cleanup and lay-up around reactor pressure vessel related to sea water intrusion event at Hamaoka Nuclear Power Station Unit 5
第9回
浜岡原子力発電所5号機主復水器細管損傷の影響調査
著者:
市川 義浩,Yoshihiro ICHIKAWA,釘本 三男,Mitsuo KUGIMOTO,渡辺 哲也,Tetsuya WATANABE,三谷 和己,Kazumi MITANI,山本 優介,Yusuke YAMAMOTO
発刊日:
公開日:
キーワードタグ:
In the process of achieving cold shutdown following the shutdown of Hamaoka Nuclear Power Station Unit 5 on May 14, 2011, the readings of conductivity meters monitoring the purity of the water in the main condensers began to rise, and the conductivity of the water in the reactor also began to rise. After cold shutdown, investigation identified that a high volume of sea water had flowed into the reactor facility due to damage to the main condenser tubes. Evaluations focusing on corrosion of materials have b...
英字タイトル:
Effect of sea water intrusion from main condenser, damaged by breakon reactor core internals, Hamaoka Unit 5